After Step 4 reboot, the Zynq may obtain a different IP via DHCP.

IP discovery strategy:
1. UART available → parse IP from boot output (fast, zero network traffic)
2. UART unavailable → scan 192.168.100.11–30 via UDP ver() probe
   (port = last_octet - 3, 0.5s timeout each, ~10s max for 20 IPs)

If IP changed → auto-update config.zynq_ip + UI field