DPS Current Measuring
Specification
Value
Condition
Voltage Range
-8V to 13V
DC Accuracy
0.1%
0.3%
After Calibration
Sense Resistors
200kΩ
50kΩ
5kΩ
0.5kΩ
10Ω
1
Sense resistors are trimmed to 1%
±5uA range
±20uA range
±200uA range
±2mA range
±60mA range
1
External Range
↩︎
Reference in New Issue