568 B
568 B
DPS Features
General
- 32 DPS Channel
- Force and sense outputs for each channel
- Current and voltage metering through dedicated channel meters
- Full four quadrant operation (source or sink, positive or negative) 1
- Five selectable forcing modes: +v, -v, +i, -i and hi-z 1
- Six selectable current clamp ranges
- Clamp function for either voltage or current
| Force Mode | Clamp target |
|---|---|
| Voltage | Current |
| Current | Voltage |
:::{card} {bdg-light}Info
P/N:JC124M060
:::
-
Not Applicable for 1A Range, 1A Range Only have Postive and source ↩︎