WIP: K7_VIH Calibration #20

Draft
yuysh wants to merge 9 commits from K7_VIH into master
Showing only changes of commit 4aa640b861 - Show all commits
@@ -57,6 +57,8 @@
3. 在ClampI模式下(FVMV/FVMI),若Clamp值与Force值接近(如80mA档位Clamp60mA,Force70mA;2mA档位Clamp1mA,Force1.5mA)则Force输出与Sense管脚及对应信号链均会出现震荡,且在极端情况下震荡 ***可能不收敛*** <a id="custom-anchor3"></a>
![ClampI2](../../_images/NewDPS/clamp_001.bmp)
![ClampI](../../_images/NewDPS/clamp_003.png)
### 3.2 原因分析